Electrical Uplift Pressure Sensor

Electrical Uplift Pressure Sensor

The uplift pressure measuring device consists of a perforated/non-perforated pipe of 50 mm dia of adequate strength. The pipe is inserted in a drilled hole in the foundation from the instrumentation gallery to the required depth. To the other end of the pipe in the gallery model, the EPU-20Vuplift pressure sensor is connected. Model EPU-20V uplift pressure sensor incorporates the latest vibrating wire technology to provide remote digital readout of fluid and/or water pressure in standpipes, boreholes, and embankments. It is similar to the model EPP-30V piezometer except that instead of the special filter, a 25 mm BSP adaptor is provided for the pipe connection. The water oozing through internal pores or seams in rock formations of dam foundations, mass concrete/foundation soil of structures, reclaimed land soil, etc., percolates upward through the pipe to the sensor

Description

The uplift pressure measuring device consists of a perforated/non-perforated pipe of 50 mm dia of adequate strength. The pipe is inserted in a drilled hole in the foundation from the instrumentation gallery to the required depth. To the other end of the pipe in the gallery model, the EPU-20Vuplift pressure sensor is connected. Model EPU-20V uplift pressure sensor incorporates the latest vibrating wire technology to provide remote digital readout of fluid and/or water pressure in standpipes, boreholes, and embankments. It is similar to the model EPP-30V piezometer except that instead of the special filter, a 25 mm BSP adaptor is provided for the pipe connection. The water oozing through internal pores or seams in rock formations of dam foundations, mass concrete/foundation soil of structures, reclaimed land soil, etc., percolates upward through the pipe to the sensor

Compare Our Products

Model EPU-20V
Model EPU-20V

Instrument Name

Uplift pressure sensor

—

—

Sensor Type

Vibrating wire

—

—

Construction

25 mm BSP adaptor is provided for pipe connection, in place of filter

—

—

Application

Monitor uplift pressure of water in foundation of dams and concrete structures

—

—

Parameter

Uplift pressure

—

—

Range

0.2, 0.35, 0.5, 1.0 MPa; specify

—

—

Key Testing / Calibration

Thermal cycling (-20 to +80°C), Pressure cycling (2000 cycles), individually temperature compensated, reverse pressure test, individually calibrated providing high accuracy & repeatability

—

—

Key Feature/Advantage

Hermetically sealed with electron beam welding

—

—

Protection (Waterproofing)

IP-68, water resistant up to its full range

—

—

Dimension (mm)

42 Ø x 210 L

—

—