The ELC-30S-H is a high capacity center hole resistive strain gage type load cell. It is used to determine the load in rock bolts, tieback anchors, etc through a center hole. It is similar to the ELC-30S load cell. It comprises of sixteen 350 Ohm resistance strain gages, wired to form a 1400 Ohm bridge, inside a stainless steel cylinder of high steel strength, in a load cell with a capacity above 5000 kN. The 3500/185 and 5000/202 load cells are welded using the electron beam welding technique.
Range (kN)/ID (mm) | 3500/185, 5000/202, 7500 /227, 10000/210, specify |
Over range capacity | 120% |
Non-linearity | ± 1 % fs(± 0.5 % fs is available) |
Output | 1.5 mV/V ± 20 % |
Excitation | 10 V DC (max. 20 V DC) |
Temperature limit | -20° to 80°C |