The Encardio-rite model EDS-20V-E strain gauge is primarily intended for strain measurement in pile foundations, segment lining of tunnels and concrete structures, etc. It is suitable for soil or concrete. The sensor is made of stainless steel and has waterproofing to prevent any ingress of water.
Range | 3000 µ strain |
Sensitivity | 1 µ strain |
Active gage length | 150 mm |
Thermistor | YSI 44005 or equivalent |
Temperature limit | -20° to 80°C |
Size l x b x h (mm) | 170 x 28.5 x 30 |
Cable connection | Four-core shielded 1 m long; specify |