search

Low-range Embedment Strain Gauge

Model EDS-20V-E Overview

The Encardio-rite model EDS-20V-E strain gauge is primarily intended for strain measurement in pile foundations, segment lining of tunnels and concrete structures, etc. It is suitable for soil or concrete. The sensor is made of stainless steel and has waterproofing to prevent any ingress of water.

Specifications

Range3000 µ strain
Sensitivity1 µ strain
Active gage length150 mm
ThermistorYSI 44005 or equivalent
Temperature limit-20° to 80°C
Size l x b x h (mm)170 x 28.5 x 30
Cable connectionFour-core shielded 1 m long; specify